Watch five rods heat up and compare the thermal resistance of a paste, a pad, and an air gap.

Enable JavaScript to use the simulator. The model and its sources are at the bottom of the page. Model and sources

Model and sources

What are you comparing?

Rods. Each 40 mm rod starts at 22 °C. The plate holds the base at a fixed temperature. The tip and sides are insulated. The model solves one-dimensional heat diffusion, ∂T/∂t = α ∂²T/∂z², with constant material properties. For CVD diamond, it uses approximate properties for the polycrystalline T-1500 grade in the same idealized geometry.

Heat flux at the probe. Fourier’s law gives the heat transfer rate per square metre of cross-section, q″ = −k ∂T/∂z. At the insulated tip it is zero throughout the experiment, even as the tip warms. At the base, the instantaneous temperature step at time zero has no finite initial flux.

How to read the scene. Gradient markers fade as the rod approaches a uniform temperature. The textures illustrate the materials and FLIR maps calculated temperatures to a fixed colour scale. The silicone oil is treated as stationary. Buoyancy, boiling and the response of an infrared camera are outside the model.

Conductivity and diffusivity. Thermal conductivity k describes how readily heat flows for a given temperature gradient, in W/(m·K). Thermal diffusivity α describes how quickly a temperature difference spreads. It is calculated as k/(ρ·cp) and is shown in mm²/s.

Layers. Steady-state thermal resistance is R = L/(k·A), in K/W, with thickness L in meters and area A in square meters. The air represents a gap with no airflow. The calculation assumes perfect contact and omits surface roughness, mounting pressure, convection, and radiation. Material properties are approximate. Use the model to compare values under the same conditions.

How the simulator was checked

A check you can repeat
Select copper and glass for two of the rods. Set the plate to 85 °C, the probe to 20 mm and the time to 10 s. Starting at 22 °C, the readings to one decimal place are 75.3 °C for copper and 22.0 °C for glass. Across 56 readings, the largest difference from an independent numerical solution was 0.0282 °C.
Resistance of a layer
Under “Thermal interfaces”, set the thickness to 0.2 mm and the area to 10 cm². Using the typical 4.3 W/(m·K) that Dow lists for its TC-5622 paste gives an ideal resistance of 0.0465 K/W. To repeat the calculation in SI units, divide 0.0002 by (4.3 × 0.001). Dow data sheet (PDF hosted by Farnell) · Fourier’s law, MIT.
Manufacturer data
For BOROFLOAT 33 glass, SCHOTT gives a conductivity of 1.2 W/(m·K) at 90 °C and a specific heat capacity of 830 J/(kg·K) between 20 and 100 °C. The model holds these properties constant. The material list identifies the source for each reference. SCHOTT technical data (PDF) · Model and sources.
What the image represents
The 3D scene renders a one-dimensional calculation. The plate is held at a fixed temperature and the rod’s tip and sides are insulated. FLIR colours represent calculated temperatures, and particles illustrate heat flow. A physical test would also be affected by heat loss to the air and by the quality of the contact.